Intellisys/Xe-series pilot solenoid controlling the inlet valve and blowdown on UP6, R-Series and Sierra units.
Also called: 1SV · load solenoid valve UP6 · Intellisys load valve
De-energised state: NC
Energised to load. On modulating machines 1SV stays energised while the modulator throttles the inlet.
How it works
Intellisys energises 1SV to route control air to the inlet valve cylinder. On unload, 1SV de-energises, the inlet valve spring closes and 3SV/blowdown vents sump pressure. Some R-Series use 1SV combined with a modulation valve for part-load control.
Coil resistance (typical, cold DC)
| Coil voltage | Resistance | Hold | Inrush |
|---|---|---|---|
| 120 VAC | 250 – 550 Ω | 11 – 17 VA | — |
| 24 VDC (Xe controllers) | 28 – 55 Ω | 9 – 14 W | — |
Typical values for the stated wattage class. Always compare against the coil tag. Open circuit = burnt winding; near 0 Ω = shorted turns.
Specifications
- Common part refs
- 39468430, 22203222, 92890297 (family varies by frame)
- Port
- 1/4" NPT, 3-way
- Coil
- Replaceable, DIN connector
Parts you can order
- $120 – $420Ingersoll Rand (OEM)1SV load solenoid / coil kitSerial-specific (e.g. 39440754, 22203991 family)
Field test procedure
- Intellisys > machine status: command LOAD and meter the coil leads.
- 120 VAC coil should read roughly 250 – 550 Ω cold. Drastically low = shorted turns.
- Inspect the small inline filter/orifice tee — IR machines commonly plug it with separator carryover varnish.
Symptoms & probable causes
- Unit runs, no pressure build1SV not energising or inlet valve poppet stuck closed.
- Will not unload / high pressure trip1SV passing internally, or blowdown line restricted.