3/2-way load/unload solenoid (generic)

Generic / universal · Load/unload solenoid

All components

The pilot valve that sends control air to the inlet valve and blowdown line. Energise to load, de-energise to unload on most machines.

Also called: loading solenoid · 1SV · SV1 · capacity control solenoid

De-energised state: NC

Normally closed P→A. Most OEMs wire it energised-to-load so a control failure or power loss drops the machine to unloaded/safe. A few older CompAir/Boge designs invert this — verify on the schematic before condemning a coil.

How it works

A 3/2-way pilot solenoid ported P (control air supply, taken downstream of the separator or from the sump), A (to the inlet valve actuator) and R (exhaust/vent). Energised: P→A, the inlet valve opens and the machine loads. De-energised: A→R, the actuator vents, the inlet valve spring-closes and the blowdown vents the sump.

Coil resistance (typical, cold DC)

Coil voltageResistanceHoldInrush
24 VDC28 – 60 Ω9 – 20 W
24 VAC8 – 25 Ω10 – 17 VA30 – 45 VA
110–120 VAC180 – 600 Ω10 – 17 VA30 – 45 VA
200–240 VAC700 – 2,400 Ω10 – 17 VA30 – 45 VA
380–480 VAC2,800 – 9,000 Ω10 – 17 VA30 – 45 VA

Typical values for the stated wattage class. Always compare against the coil tag. Open circuit = burnt winding; near 0 Ω = shorted turns.

Specifications

Body port size
1/8" – 1/4" NPT / G
Orifice
1.6 – 3.0 mm
Working pressure
0 – 150 PSIG (10 bar) pilot
Media temp
-10 to 80 °C (14 – 176 °F)
Duty
100 % ED, continuous
Enclosure
IP65 with moulded DIN 43650-A connector

Parts you can order

  • ASCO (Emerson)
    Series 210 general service
    8210G002
    $95 – $210
  • ASCO (Emerson)
    Red-Hat replacement coil
    238610-032-D (120 V/60 Hz)
    $35 – $90
  • ASCO (Emerson)
    Series 8320 3-way universal
    8320G174
    $130 – $300
  • ASCO (Emerson)
    Red-Hat II replacement coil
    238610-032-D (120/60)
    $45 – $110
  • Parker (Skinner)
    7000 series 2-way NC
    71216SN2MN00N0C111C2
    $80 – $180
  • Bürkert
    Type 6013 2/2-way
    6013 (configure by orifice/voltage)
    $110 – $240
  • Norgren
    Series 83 direct solenoid
    8320300.9101.02400
    $95 – $210
  • SMC
    VX21 2-port direct-operated
    VX2120-02-5DZ1
    $70 – $150
  • Humphrey
    410 series 3-way poppet
    410 (voltage suffix)
    $90 – $190
Open the full parts database →

Field test procedure

  1. Lock out and bleed sump pressure to 0 before removing any pilot line.
  2. Unplug the DIN connector and ohm the coil pin-to-pin. Compare with the coil's own voltage/wattage tag using the table above.
  3. Open coil (OL) = burnt winding. Near 0 Ω = shorted turns. Both mean replace the coil, not the valve body.
  4. Megger coil-to-body at 500 V: expect > 20 MΩ. Under 1 MΩ means moisture ingress — the DIN gasket is the usual culprit.
  5. With power on and the machine commanded to load, measure voltage at the coil. Voltage present + no click = failed coil or a stuck armature.
  6. Voltage present, coil good, still no load: pull the valve and check for varnish on the armature and a plugged 1.6 mm orifice.

Symptoms & probable causes

  • Machine never loads
    No coil voltage (controller output, fuse, or relay), open coil, or plugged pilot orifice.
  • Machine loads but will not unload
    Armature stuck open on varnish, or exhaust port R plugged so the actuator cannot vent.
  • Continuous air leak from the vent port
    Seat debris or a swollen elastomer seal. Rebuild kit or replace.
  • Coil burns repeatedly
    Wrong voltage coil, AC coil held off its seat (never fully pulls in), or > 10 % over-voltage.
  • Loads for a second then dumps
    Control air supply restricted, or the actuator diaphragm is leaking down.

Coil and valve body are separate parts on nearly every brand. A failed coil is a 10-minute swap; only replace the whole valve if the seat or armature is damaged.