CA7-23 (3-pole 23 A)

Sprecher + Schuh · IEC · 3-pole

All contactors

CA7-23 (3-pole 23 A)

Sprecher + Schuh · Series CA7, 45 mm frame

Sprecher + Schuh CA7-23 — a rugged IEC contactor used in North American OEM panels and as a common cross for Allen-Bradley 100-C in industrial air systems.

Ratings
AC-3 (480 V)
23 A
AC-1
40 A
Hp (3Φ)
7.5 HP @ 230 V · 15 HP @ 460 V
Three-phase HP
7.5 HP @ 230 V · 15 HP @ 460 V
Coil data
Available coil voltages
24, 120, 208, 240, 277, 480, 600 VAC 60 Hz; DC and electronic coil options
Inrush VA
≈ 120 VA
Sealed (holding) VA
≈ 10 VA
Pickup voltage
0.85–1.1 × rated
Dropout voltage
0.3–0.6 × rated
Typical measured coil resistance (±15%, ballpark)
24 VAC≈ 5–11 Ω
120 VAC≈ 120–250 Ω
480 VAC≈ 2,000–3,900 Ω

OL = open coil · near zero = shorted turns · coil-to-frame must read >1 MΩ.

Coil resistance checker

Pick the coil voltage, enter your meter reading across A1–A2 (coil disconnected), and compare it to the expected ballpark.

Ω
This model (24 VAC table value)5 Ω11 Ω
Generic mid-frame 24 VAC4 Ω9 Ω

OL = open coil. 0–2 Ω = shorted turns (often from a cooked transformer). Ballpark only (±15%+); electronic wide-range coils (e.g. ABB AF) read misleading values — test those at rated voltage instead. Always measure coil-to-frame too: must be >1 MΩ.

Terminals & accessories
Power/coil terminals: Box lug to 6 AWG; finger-safe
Auxiliary contacts: 1 built-in; CA7-PV front and CA7-KC side blocks
Companion overload: CEP7 electronic or CT7 thermal overload, direct-mount
Cross-references
Field notes
  • CA7 bodies are dimensionally close to the 100-C but the mounting and aux blocks are brand-specific — don't mix accessories.
  • CEP7 electronic overloads have a trip-class dial and a phase-loss function that trips fast on single-phasing — a real benefit on 3-phase recips.
  • Sprecher + Schuh publishes a full cross-reference in Section A of their e-catalog; useful when replacing obsolete brands.
Sprecher + Schuh resources

Links go to the manufacturer's current catalog or product page — model-specific pages are often retired, so these stay live.