Signals a plugged separator element by monitoring pressure drop across it.
Also called: separator dP · element restriction switch
De-energised state: NO
Normally open, closes on rising dP (typical alarm wiring). Verify against the schematic.
How it works
Either a mechanical dP switch tapped before and after the element, or two transducers differenced in software. A new element runs around 2 – 4 PSI dP; change it above roughly 10 – 12 PSI.
Specifications
- New element dP
- 2 – 4 PSI (0.15 – 0.3 bar)
- Change-out dP
- 10 – 12 PSI (0.7 – 0.8 bar)
- Contact
- Pilot duty, SPDT typical
Parts you can order
- $70 – $260Generic industrialSeparator differential pressure switchBy dP set point (typically 8–12 psid)
Field test procedure
- Ohm the contact at known dP and compare with the switch tag.
- Confirm the tapping lines are clear — plugged taps make a good element look perfect or terrible.
Symptoms & probable causes
- Alarm with a new elementBlocked sensing line, wrong switch setting, or an MPV stuck closed.
More sensor