Oil level sensor / switch

Generic / universal · Sensor

All components

Float, capacitive or optical sensor that trips or warns on low sump oil level.

De-energised state: NC

Usually closed with correct oil level; opens on low (fail-safe). Confirm per machine — some are reversed.

How it works

A float reed switch, capacitive probe or optical prism in the sump wall changes state when oil falls below the safe level. Most controllers alarm first and trip on continued low level.

Specifications

Contact rating
Pilot duty, typically 0.5 – 1 A @ 24 – 240 V
Reed switch resistance
< 1 Ω closed, OL open

Parts you can order

  • Generic industrial
    Sump oil level switch
    By stem length and float
    $60 – $240
Open the full parts database →

Field test procedure

  1. With correct level and machine locked out, ohm the switch: NC type should read < 1 Ω.
  2. Foam from the wrong oil or an over-full sump makes a good sensor chatter.

Symptoms & probable causes

  • Low oil alarm with a full sight glass
    Failed sensor, foaming oil, or a shorted lead.
More sensor