EQP-Global / EKM3 Premium

Toshiba

AirCompDX - Field Reference for Air Compressor Techs
All motors
Toshiba

EQP-Global / EKM3 Premium

Compressors, pumps, fans; IEEE 841 variant available.

Nameplate
Phase
3-Phase
HP range
1 – 800 HP
Voltage codes
230/460 V · 460 V · 575 V
NEMA frames
143T – 5011
Enclosure
TEFC cast iron
Poles / RPM
2, 4, 6, 8
Efficiency
NEMA Premium
Insulation class
F (Class B rise)
Service factor
1.15
Lead connection diagrams
9-lead Wye (High voltage · 460 V)
L1 ─┬─ T1 ── T7
L2 ─┬─ T2 ── T8
L3 ─┬─ T3 ── T9
     T4 ─┐
     T5 ─┼── tied together (neutral point)
     T6 ─┘

Tie T4-T5-T6 together and insulate. Feed line to T1/T2/T3; jumper T7-T1, T8-T2, T9-T3.

9-lead Delta (Low voltage · 230 V)
L1 ─┬─ T1 ── T6 ── T7
L2 ─┬─ T2 ── T4 ── T8
L3 ─┬─ T3 ── T5 ── T9

Parallel pairs: T1-T6-T7, T2-T4-T8, T3-T5-T9. No neutral tie.

Schematics & manuals

Links point to the manufacturer's own PDF hosting. If a link 404s, search the model number on the manufacturer's Download Center — filenames change with revision.

The connection charts above are the NEMA MG-1 industry-standard patterns most brands follow. Always confirm the exact chart printed inside your motor's peckerhead lid before landing leads — voltage-code and lead-tag conventions vary between OEMs and production years.