Century Compressor Duty 1φ

Century (Regal Rexnord, ex-A.O. Smith)

AirCompDX - Field Reference for Air Compressor Techs
All motors
Century (Regal Rexnord, ex-A.O. Smith)

Century Compressor Duty 1φ

Big-box store tank-mount replacement motors.

Nameplate
Phase
Single-Phase
HP range
1 – 7.5 HP (advertised 'SPL' ratings vary)
Voltage codes
115/230 V · 230 V
NEMA frames
56 – 184T
Enclosure
ODP
Poles / RPM
2 (3450 RPM typical)
Efficiency
Standard
Insulation class
B
Service factor
1.0 – 1.15 (nameplate varies)
Lead connection diagrams
Single-phase capacitor-start (CW rotation)
L1 ── T1 (main)
L2 ── T4 (main)
Start winding: T5-T8 with start cap + centrifugal switch
Rotation reverse: swap T5 and T8

For CCW rotation, swap the two start-winding leads (T5↔T8), not the line leads.

Field notes
  • Watch for inflated 'SPL' (Special) horsepower ratings — the true continuous HP is usually the FLA/SF math, not the sticker number.
  • Use nameplate FLA for overload sizing, never the marketing HP.

The connection charts above are the NEMA MG-1 industry-standard patterns most brands follow. Always confirm the exact chart printed inside your motor's peckerhead lid before landing leads — voltage-code and lead-tag conventions vary between OEMs and production years.