Xe-90M
The 90M is the usual retrofit target when replacing an obsolete Intellisys SG on an R-Series — sensors change but the panel cutout is close.
Manufacturer
Ingersoll Rand
Display
3.5" backlit graphic LCD with soft keys and status LED bar.
Years produced
~2014 – present. Mid tier of the Xe family.
Power supply
24 VDC from package transformer; battery-backed clock.
Ambient range
0 – 46 °C.
Protection rating
IP54 front.
Relay outputs
Main/star/delta, load, blowdown, dryer enable, common alarm, remote-run, spare programmable relay.
Replaces
Intellisys SG, Xe-70M (on larger frames)
Used on
- IR R-Series 37–75 kW fixed speed
- Sierra oil-free (select frames)
- UP6-Series larger packages
Features
- Integrated sequencing of up to 4 compressors without an external master
- Energy-saving 'Progressive Adaptive Control' — reduces unloaded run time automatically
- Full alarm and event history with hour-stamped entries
- Dual pressure setpoint with schedule
Interfaces
- Modbus RTU (RS-485)
- Ethernet Modbus TCP (option)
- Volt-free contacts
- X-Series sequencing link
Sensor inputs
- Package discharge pressure
- Sump pressure
- Airend discharge temp (RTD)
- Inlet vacuum (option)
- Separator ΔP
- Coolant filter ΔP
Fault code lookup
First checks
- Coolant level
- Cooler core / aftercooler fouling
- Thermal valve element
First checks
- Inlet valve not closing on unload
- Blowdown solenoid failed closed
- Check MPV / check valve
First checks
- Change filter, reset the timer
- Cold-start ΔP alarms are normal until fluid warms
First checks
- Confirm control mode is set to Remote
- Check the remote loop contact stays closed long enough
- Look for a standing alarm blocking start
First checks
- Inlet valve stuck closed
- Blowdown valve leaking
- Verify sump transducer against gauge
First checks
- Check contactor aux contact and wiring
- Look for welded or chattering contactor
- Verify 24 V coil supply
First checks
- Drive powered and not in fault
- RS-485 A/B polarity and termination
- Check drive parameter for control source
Fault list is non-exhaustive and firmware-dependent. Always confirm against the controller’s on-screen help or OEM manual.
Sensor pin resistance & signal values
Pin-level resistance and signal values for the sensor types this controller uses. Works offline. De-energise the panel and lift one lead before ohming any element.
Wiring notes
- Sequencing between Xe controllers is RS-485 daisy-chained — no star topology, 120 Ω at both physical ends
- Keep transducer runs out of the starter compartment; VFD carrier noise shows as jittery pressure
Known issues & field notes
- Display ribbon connector backs out with panel vibration — reseat before condemning the CPU
- Firmware before 2017 mis-handles daylight-saving on scheduled start/stop