iCommand-Touch
The built-in 4-machine sequencing makes this one of the cheapest ways to sequence a small room — set it up before quoting a separate master controller.
Manufacturer
FS-Curtis
Display
7 in color resistive touchscreen, graphic trend and mimic screens.
Years produced
~2015 – present on Nx / NxB / NXHE series.
Power supply
24 VDC internal.
Ambient range
0 – 46 °C.
Protection rating
IP65 front panel.
Relay outputs
Main/star/delta, load solenoid, dryer, alarm, auto-restart.
Used on
- FS-Curtis Nx / NxB series 5–350 hp
- NxHE variable speed
- Some FSC-Maxion rebadges
Features
- Full-color trending of pressure and temperature
- Built-in base-load sequencing of up to 4 machines without a master panel
- USB event-log and parameter backup
- iConnect cloud telematics option
Interfaces
- Modbus RTU/TCP
- Ethernet for iConnect telematics
- USB for log export and firmware
Sensor inputs
- Airend discharge temperature (PT100)
- Package pressure transducer
- Sump pressure transducer
- VFD feedback on NxHE / VSD builds
Fault code lookup
First checks
- Oil level / cooler
- Thermal bypass valve
- PT100 loop check ~100 Ω at 0 °C
First checks
- Connector and cable
- Loop current measurement
- Sensor replacement
First checks
- Reset and measure running amps
- Phase imbalance
- Airend rotation free
First checks
- Drive display code
- Heatsink cleanliness
- Line voltage quality
First checks
- E-stop buttons
- Safety relay status LEDs
First checks
- Perform kit service
- Reset corresponding timer only
Fault list is non-exhaustive and firmware-dependent. Always confirm against the controller’s on-screen help or OEM manual.
Sensor pin resistance & signal values
Pin-level resistance and signal values for the sensor types this controller uses. Works offline. De-energise the panel and lift one lead before ohming any element.
Wiring notes
- Touchscreen is a separate HMI from the I/O board — a dead screen with a running unit usually means the HMI ribbon or 24 V HMI supply, not the control board
- USB firmware updates must use FAT32 sticks under 32 GB
- Sequencing between machines uses the RS-485 terminals marked MB-A/MB-B
Known issues & field notes
- Resistive touch calibration drifts in hot cabinets — recalibrate from the hidden corner-touch service routine
- Units with early iConnect modems lose cloud connection after carrier 3G sunsets — upgrade to the LTE module
Service menu PIN set by distributor at commissioning.
Manuals & literature