iCommand-Touch

FS-Curtis

iCommand-Touch

The built-in 4-machine sequencing makes this one of the cheapest ways to sequence a small room — set it up before quoting a separate master controller.

Manufacturer
FS-Curtis
Display
7 in color resistive touchscreen, graphic trend and mimic screens.
Years produced
~2015 – present on Nx / NxB / NXHE series.
Power supply
24 VDC internal.
Ambient range
0 – 46 °C.
Protection rating
IP65 front panel.
Relay outputs
Main/star/delta, load solenoid, dryer, alarm, auto-restart.
Used on
  • FS-Curtis Nx / NxB series 5–350 hp
  • NxHE variable speed
  • Some FSC-Maxion rebadges
Features
  • Full-color trending of pressure and temperature
  • Built-in base-load sequencing of up to 4 machines without a master panel
  • USB event-log and parameter backup
  • iConnect cloud telematics option
Interfaces
  • Modbus RTU/TCP
  • Ethernet for iConnect telematics
  • USB for log export and firmware
Sensor inputs
  • Airend discharge temperature (PT100)
  • Package pressure transducer
  • Sump pressure transducer
  • VFD feedback on NxHE / VSD builds
Fault code lookup
First checks
  • Oil level / cooler
  • Thermal bypass valve
  • PT100 loop check ~100 Ω at 0 °C
First checks
  • Connector and cable
  • Loop current measurement
  • Sensor replacement
First checks
  • Reset and measure running amps
  • Phase imbalance
  • Airend rotation free
First checks
  • Drive display code
  • Heatsink cleanliness
  • Line voltage quality
First checks
  • Perform kit service
  • Reset corresponding timer only

Fault list is non-exhaustive and firmware-dependent. Always confirm against the controller’s on-screen help or OEM manual.

Sensor pin resistance & signal values

Pin-level resistance and signal values for the sensor types this controller uses. Works offline. De-energise the panel and lift one lead before ohming any element.

Wiring notes
  • Touchscreen is a separate HMI from the I/O board — a dead screen with a running unit usually means the HMI ribbon or 24 V HMI supply, not the control board
  • USB firmware updates must use FAT32 sticks under 32 GB
  • Sequencing between machines uses the RS-485 terminals marked MB-A/MB-B
Known issues & field notes
  • Resistive touch calibration drifts in hot cabinets — recalibrate from the hidden corner-touch service routine
  • Units with early iConnect modems lose cloud connection after carrier 3G sunsets — upgrade to the LTE module

Service menu PIN set by distributor at commissioning.