MDR 3

Three-phase switch that carries motor current, optional thermal overload

All pressure switches
Condor · MDR 3

MDR 3

The reason Condor shows up on three-phase machines: MDR 3 builds switch all three motor poles directly and can be ordered with an integrated adjustable thermal overload, so a small three-phase recip needs no separate starter.

Specifications

Action
Standard — contacts open on rising pressure
Adjustable range
Selected by build; common industrial compressor ranges
Differential
Adjustable hysteresis (adjustable)
Factory settings
Per OEM build
Ports
Metric G 1/4 typical
Unloader
Optional integrated unloader
Lever / disconnect
Integral rotary handle
Enclosure
Sealed industrial housing
Temperature
Per datasheet

Electrical

  • Three-phase, 400 V class construction
  • Optional integrated thermal overload relay with adjustable trip current — set it to motor FLA
  • Integral on/off handle switching all poles

Size against motor full-load amps with the motor amperage calculator, and check feeder sizing with the voltage drop calculator.

Adjustment

  1. Switching point screw, hysteresis screw, and (if fitted) the overload current dial — three separate settings.
  2. Set the overload dial to nameplate FLA, not to the breaker size.
Before you open the cover

Kill power at the disconnect and lock out. Bleed the tank to 0 psi. Never set cut-out above the tank data-plate MAWP. Verify your numbers first in the cut-in / cut-out calculator.

Best fit

  • Small three-phase recips up to the switch's rated HP
  • Machines where panel space is tight

Watch out

  • Above the switch's rated horsepower you must go back to a contactor. Do not oversize by hoping.
  • An integrated overload still needs annual verification — check trip current against the motor plate.

Cross-references

  • Square D 9013 + separate contactor/overload
  • Any IEC starter + pilot-duty pressure switch