MDR 2 / MDR 11

German industrial switch with separate switching-point and hysteresis screws

All pressure switches
Condor · MDR 2

MDR 2 / MDR 11

The high-performance Condor switch used on Atlas Copco, Chicago Pneumatic, ABAC, Fini and most European recips. Two independent adjusting screws set the switching point and the hysteresis, and the integrated rotary on/off handle acts as a motor disconnect. KEMA KEUR tested.

Specifications

Action
Standard — contacts open on rising pressure
Adjustable range
Multiple pressure ranges from low-pressure pump duty up to industrial compressor ranges — selected by build
Differential
Independently adjustable hysteresis screw (standard on MDR 2) (adjustable)
Factory settings
Set per OEM build; typically 8 bar (116 psi) or 10 bar (145 psi) cut-out on European recips
Ports
Metric (G 1/4 typical) — expect an adapter on North American plumbing
Unloader
Optional integrated unloader valve
Lever / disconnect
Integral rotary on/off handle
Enclosure
IP54-class sealed housing typical
Temperature
Per datasheet build

Electrical

  • Single-phase and three-phase versions available
  • Integral on/off rotary handle switches all poles
  • Optional operating-hours counter kit mounts to the cover in four positions

Size against motor full-load amps with the motor amperage calculator, and check feeder sizing with the voltage drop calculator.

Adjustment

  1. Larger screw = switching point (moves both cut-in and cut-out).
  2. Smaller screw = hysteresis (differential only).
  3. Adjust switching point first, then hysteresis, then re-verify both across a full cycle.
Before you open the cover

Kill power at the disconnect and lock out. Bleed the tank to 0 psi. Never set cut-out above the tank data-plate MAWP. Verify your numbers first in the cut-in / cut-out calculator.

Best fit

  • Imported and European recips
  • Installs that need a disconnect built into the switch
  • Jobs where you must tune the differential precisely

Watch out

  • Metric threads. Do not force NPT into a G 1/4 port — it will leak and can crack the body.
  • The hour-counter cover is a genuine service aid; keep it when swapping the switch body.

Cross-references

  • Square D 9013GHG (adjustable differential equivalent)
  • MDR 11 for smaller single-phase machines