Logix (aftermarket / OEM shared)

Multiple (originally Powerex / Champion small units)

AirCompDX - Field Reference for Air Compressor Techs

Logix (aftermarket / OEM shared)

Common on medical-air and lab-air scroll skids. The controller name 'Logix' shows up on multiple OEM panels — always confirm firmware and I/O map before swapping.

Manufacturer
Multiple (originally Powerex / Champion small units)
Display
2-line 20-char LCD with 4 status LEDs.
Years produced
Late 1990s – present, multiple hardware families.
Power supply
24 VDC control, 120 VAC input.
Ambient range
0 – 46 °C.
Protection rating
IP54 front.
Relay outputs
One contactor coil output per scroll head + alarm + dryer.
Used on
  • Powerex medical scroll modules
  • Champion small-frame commercial units
  • OEM-branded remakes on various shop compressors
On AirCompDX
Features
  • Pressure-based cycling of 2–4 scroll heads
  • Hour equalization / lead-lag rotation
  • Alarm relay output
Interfaces
  • RS-485 Modbus RTU (option)
  • 24 VDC I/O
  • Digital dryer output
Sensor inputs
  • Per-head discharge temp
  • System pressure (4–20 mA)
  • Optional dewpoint
Common fault codes
First checks
  • Check head cooling fan
  • Verify inlet filter
  • Test thermistor / RTD
First checks
  • Check leaks
  • Verify head loading sequence
  • Confirm pressure sensor calibration
First checks
  • Verify sensor calibration; check safety relief

Fault list is non-exhaustive and firmware-dependent. Always confirm against the controller’s on-screen help or OEM manual.

Wiring notes
  • 24 VDC control, 120 VAC contactor coils; one contactor per scroll head
Known issues & field notes
  • Hour equalization drifts if a head is manually disabled — reset lead/lag pointer after service
  • Alarm relay wetted vs dry-contact varies by OEM build — verify before wiring to plant BMS
Manuals & literature
Powerexsupport portal

Manuals hosted per-product — search model below

Your manuals

Sign in to upload and pin your own PDF manuals to this controller.