Xe-70M / Xe-90M / Xe-145M / Xe-300M

Ingersoll Rand

AirCompDX - Field Reference for Air Compressor Techs

Xe-70M / Xe-90M / Xe-145M / Xe-300M

Xe replaced the long-running Intellisys SG/SGN in 2016+. If replacing an SGN with an Xe, confirm sensor wiring polarity (RTD vs thermistor) — cross-wiring shows up as immediate high-temp shutdown on start.

Manufacturer
Ingersoll Rand
Display
Xe-70M: 3.5" color; Xe-90M: 4.3" color; Xe-145M: 7" color touch; Xe-300M: 7" color touch with sequencing screens.
Years produced
~2016 – present. Replaced the long-running Intellisys SG/SGN family.
Power supply
24 VDC control from onboard PSU (120/230 VAC input). Battery-backed RTC.
Ambient range
0 – 46 °C. Xe-70M rated for enclosure ambient; Xe-145M/300M cabinet-mount.
Protection rating
IP54 front, IP20 rear.
Relay outputs
Configurable digital outputs for main / star / delta contactors, load solenoid, blowdown, alarm, dryer, remote-run.
Replaces
Intellisys SG, Intellisys SGN
Used on
  • Ingersoll Rand R-Series RS 7.5–160 (contact-cooled)
  • Ingersoll Rand R-Series RS 90n–160n Next-Gen
  • Ingersoll Rand Nirvana / NirvanaXE (VSD)
  • Retrofit for older Intellisys SG/SGN controllers
On AirCompDX
Features
  • System Automation to sequence up to 4 (Xe-145M) or 12 (Xe-300M) units
  • Progressive Adaptive Control (PAC) load management
  • Multi-language interface, on-board trending (up to 30 days on Xe-300M)
  • Integrated dryer control on TAS units
  • PORO (Power-Out Restart Option) with configurable delay — safety-critical setting
Interfaces
  • Ethernet (Modbus TCP, ICONS remote monitoring)
  • USB service port
  • Digital I/O for remote start/stop, load, ES
  • Optional Modbus RTU, Profibus, EtherNet/IP gateway
Sensor inputs
  • Airend discharge temperature (RTD)
  • Package discharge temperature
  • Sump pressure
  • Line/system pressure
  • Coolant filter ΔP (option)
  • Separator ΔP (option)
  • Motor winding temperature (thermistor input on n-series)
Common fault codes
First checks
  • Check oil level and cooler cleanliness
  • Verify oil thermostatic valve and cooler bypass
  • Test airend discharge RTD
First checks
  • Reset overload, check trip class vs FLA
  • Verify voltage balance across all phases
  • Confirm no airend seizure
First checks
  • Release E-stop, check remote loop
  • Verify 24 V on safety input
First checks
  • Clean cooler; free fan blade; check bearings
  • Verify fan contactor & OL setting
First checks
  • Verify 24 VDC on remote stop input
  • Check jumper on TB if not using remote
  • Confirm run-permissive wiring integrity
First checks
  • Check start-permissive chain
  • Verify no active alarms
  • Confirm mode = remote
First checks
  • Check wiring polarity
  • Compare RTD resistance to table
  • Look for water intrusion at connector
First checks
  • Change filter and verify O-ring
  • Check for cold-start high ΔP masking real issue
  • Sample oil for contamination
First checks
  • Replace air filter
  • Check inlet valve movement
  • Verify vacuum switch calibration
First checks
  • Change separator element as a full kit
  • Check scavenge line
  • Inspect fluid for foaming
First checks
  • Check blowdown solenoid coil and orifice
  • Inspect MPCV (min pressure check valve) for stuck poppet
  • Verify inlet valve fully closes
First checks
  • Check load/unload setpoints
  • Verify inlet valve closes at unload
  • Look for stuck-open bypass or MPCV
First checks
  • Check inlet valve movement
  • Look for large leak between airend and separator
  • Verify blowdown closes
First checks
  • Change Ultra Coolant / Ultra EL Coolant as set
  • Sample old coolant for TAN & metals
  • Reset timer only
First checks
  • Verify ΔP before replacing (may still be good)
  • Reset service counter

Fault list is non-exhaustive and firmware-dependent. Always confirm against the controller’s on-screen help or OEM manual.

Wiring notes
  • 24 VDC control power from onboard PSU
  • PORO (Power Out Restart Option) toggle in service menu — safety-critical (LOTO warning required)
  • TAS integrated dryer wired to Xe I/O terminals; standalone dryers via digital in/out
  • Modbus RTU on 2-wire RS-485; terminate 120 Ω at both ends of the daisy-chain
Terminal & connector map

Pinouts distilled from OEM wiring diagrams. Exact silk-screen labels and pin numbering vary by hardware revision and package options — always confirm against the machine’s as-built wiring diagram before landing a wire.

Connectors to the controller
  • P1 – 24 VDC control power (screw terminals, top of controller)
  • P2 – RS-485 X-Series sequencer bus (A/B/GND) — daisy-chain to lead controller
  • P3 – RJ45 Ethernet (Modbus TCP)
  • P4 – RTD sensor harness (keyed connector) to airend discharge / package discharge sensors
  • P5 – 4–20 mA transducer harness (line pressure, sump pressure, sep ΔP)
  • P6 – digital I/O to starter panel (star/delta, blowdown, remote start/stop, common trouble)
P1 – PowerControl power
PinSignalTypeConnects to
+24+24 VDC24 VDCT1 secondary +
0V0 V return24 VDC ret.T1 secondary −
PEProtective earthPEPanel ground bar
P4 – RTD inputsAirend & package RTDs
PinSignalTypeConnects to
1RTD 1/2/3Airend discharge (2ATT)PT100 3-wire2ATT sensor at airend outlet
2RTD 1/2/3Package discharge (3ATT)PT100 3-wire3ATT sensor at aftercooler out
3RTD 1/2/3Injection temp (option)PT100 3-wireInjection temp sensor

Xe uses PT100 (SGN often thermistor) — verify sensor type before energizing.

P5 – Pressure4–20 mA transducers
PinSignalTypeConnects to
1AVPT +/−Package discharge pressure4–20 mA1AVPT transducer
2AVPT +/−Sump pressure4–20 mA2AVPT transducer
ΔP +/−Separator ΔP4–20 mASep ΔP transducer
P6 – Digital I/OStarter, remote, alarm
PinSignalTypeConnects to
1MMain contactor coil (star/delta or ATL)24 VDC out1M main contactor
1SStar contactor coil24 VDC out1S star contactor
1DDelta contactor coil24 VDC out1D delta contactor
1SVLoad / blowdown solenoid24 VDC out1SV load solenoid
RS+/RS−Remote start (dry)dry contact inCustomer PLC
RSt+/RSt−Remote stop (dry)dry contact inCustomer PLC
CT+/CT−Common trouble relayrelay outMaster alarm / BMS
Known issues & field notes
  • PORO on by default from factory on some builds — verify with customer before commissioning
  • USB firmware update fails on FAT32 sticks > 32 GB — use small industrial-grade stick
  • Touchscreen unresponsive after long dwell — cold-cycle 24 V PSU
  • MPCV false 'code 27' alarms on cold Ultra Coolant — recheck after 20 min run
Retrofit notes

SGN → Xe retrofit: sensor pinouts and RTD types differ. Wire per Xe wiring diagram, not old SGN loom. Confirm sump pressure sensor polarity.

Firmware notes

Xe firmware families are frame-specific — do not cross-flash between Xe-70M and Xe-145M without verified image.

Service level requires 4-digit PIN (dealer-set). Do not share OEM defaults publicly.