Neuron XT

ELGi

Neuron XT

ELGi's tropical parameter sets are the real deal — on hot-climate installs, confirm the machine is running the high-ambient profile before chasing phantom high-temp trips.

Manufacturer
ELGi
Display
Color TFT, icon + plain-text menus, multi-language.
Years produced
~2018 – present on EG / EQ / AB series.
Power supply
24 VDC internal.
Ambient range
0 – 50 °C (tropical-rated builds).
Protection rating
IP54 front.
Relay outputs
Contactors, load solenoid, blowdown, fan, dryer, alarm.
Used on
  • ELGi EG series global screws
  • EQ small industrial
  • AB oil-free (variant firmware)
Features
  • Air~Alert IoT monitoring with predictive alerts
  • Built-in 4-machine sequencing
  • High-ambient parameter sets for tropical installs
  • Energy report pages
Interfaces
  • Modbus RTU standard
  • Air~Alert telematics (option)
  • USB log export
Sensor inputs
  • Airend discharge temperature (PT100)
  • Package pressure transducer
  • Sump pressure
  • Oil filter and separator differential switches
  • VFD feedback (VSD builds)
Fault code lookup
First checks
  • Oil level / cooler
  • Thermal valve
  • Ambient above rating — check tropical kit presence
First checks
  • Drive display
  • Heatsink cleaning
  • Line conditions
First checks
  • Replace element
  • Check oil type and interval
First checks
  • Signal strength at antenna
  • SIM status
  • Advisory only — machine continues

Fault list is non-exhaustive and firmware-dependent. Always confirm against the controller’s on-screen help or OEM manual.

Sensor pin resistance & signal values

Pin-level resistance and signal values for the sensor types this controller uses. Works offline. De-energise the panel and lift one lead before ohming any element.

Wiring notes
  • Tropical builds have different fan-control parameters — verify parameter set after any board swap
  • Modbus and Air~Alert share the comm card; register conflicts if both polled aggressively
  • Sensor harness uses sealed connectors — replace seals after service
Known issues & field notes
  • High-humidity installs see connector corrosion despite seals — dielectric grease at every service
  • Air~Alert aggressive-polling firmware early builds could watchdog the display — update firmware

Service PIN via ELGi service network.

Manuals & literature
Your manuals