CompAir DELCOS Pro / XL / 3100

CompAir (Gardner Denver / Ingersoll Rand)

CompAir DELCOS Pro / XL / 3100

CompAir shares parent (Gardner Denver / Ingersoll Rand) with GD — some sensors are cross-compatible but part numbers differ.

Manufacturer
CompAir (Gardner Denver / Ingersoll Rand)
Display
DELCOS XL: 5.7" TFT color; DELCOS Pro: 4-line monochrome.
Years produced
DELCOS Pro ~2008 – 2016; DELCOS XL ~2016 – present. DELCOS 3100 for large frames.
Power supply
24 VDC control power.
Ambient range
0 – 46 °C.
Protection rating
IP54 front.
Relay outputs
Star / delta / main, blowdown, dryer, alarm, remote-run.
Replaces
DELCOS 1000, DELCOS 3000
Used on
  • CompAir L-Series rotary screws
  • CompAir D-Series
  • CompAir Cyclon
  • CompAir DH & DL two-stage
On AirCompDX
Features
  • Sequencing via SmartAir Master
  • Assure remote monitoring
  • Modulation, load/unload, or dual control
Interfaces
  • Ethernet Modbus TCP
  • RS-485 Modbus RTU
  • Optional Profibus
Sensor inputs
  • Airend discharge temp
  • Line pressure
  • Sump pressure
  • Separator ΔP
  • Ambient (option)
Fault code lookup

Fault list is non-exhaustive and firmware-dependent. Always confirm against the controller’s on-screen help or OEM manual.

Sensor pin resistance & signal values

Pin-level resistance and signal values for the sensor types this controller uses. Works offline. De-energise the panel and lift one lead before ohming any element.

Wiring notes
  • 24 VDC control; 120/230 VAC coil options depending on region
Known issues & field notes
  • DELCOS Pro CPU battery drift after long shutdown — replace at each major service
Field tips (web-sourced)

Distilled from public OEM manuals and community technician references. Cross-check the on-machine service manual before commissioning.

Menu / access
  • Arrow keys navigate the menu tree; the check-mark key accepts. 'ESC' backs up one level.
  • Customer settings (pressure band, timers) are un-locked; service settings (calibration, VFD tuning, PM timers) require the technician password set at commissioning.
  • Event history is under Info → History — last 50 events with elapsed hours and a sensor snapshot.
Field gotchas
  • DELCOS Pro (round display) and DELCOS XL (touch) share the parameter tree — Pro training transfers to XL.
  • 'PM Timer' countdown is per-service, not cumulative — resetting the oil-change timer does NOT reset the separator or air-filter timers.
  • Reset a PM timer by long-pressing the check-mark on the timer line in Info → Service.
Manuals & literature
Ingersoll Randsupport portal

Customer Care → Manuals & Parts (login often required)

Direct PDFs
  • Open
  • Open
  • Open
Your manuals

Sign in to upload and pin your own PDF manuals to this controller.