CP ES3000 / ES4000

Chicago Pneumatic

AirCompDX - Field Reference for Air Compressor Techs

CP ES3000 / ES4000

ES-series shares hardware architecture with Atlas Copco Elektronikon Mk4 (shared parent). Many sensors and harnesses cross-reference to AC part numbers with a CP label.

Manufacturer
Chicago Pneumatic
Display
ES3000: 2×16 backlit LCD, 6-key membrane. ES4000: 4-line graphic LCD.
Years produced
ES3000 ~2005 – 2015; ES4000 ~2012 – 2020.
Power supply
24 VDC control power, 120/230 VAC input.
Ambient range
0 – 46 °C.
Protection rating
IP54 front.
Relay outputs
Main / star / delta, blowdown, dryer, alarm, load solenoid, remote-run.
Replaced by
CP Air Control / CP Touch
Used on
  • CP CPA / CPB / CPC rotary screws 5–75 hp
  • Early CP QRS series
  • CP CPM medical / dental packages
Features
  • Load/unload with dual-pressure band
  • Weekly timer with 8 events
  • Auto-restart after power failure (jumper selectable)
  • Service reminders by hours
Interfaces
  • RS-485 Modbus RTU
  • Digital I/O terminal strip
  • Optional Ethernet gateway (ES4000)
Sensor inputs
  • Airend discharge temp (PT100)
  • Line pressure (4–20 mA)
  • Sump pressure (4–20 mA)
  • Motor PTC
Common fault codes
First checks
  • Reset overload
  • Verify FLA & phase balance
  • Test PTC continuity
First checks
  • Unload setpoint & deadband
  • Inlet valve closure
  • Check for stuck load solenoid
First checks
  • Verify 3 phases
  • Swap 2 phases for rotation
  • Check phase-monitor relay
First checks
  • Inspect wiring & polarity
  • Test sensor against reference

Fault list is non-exhaustive and firmware-dependent. Always confirm against the controller’s on-screen help or OEM manual.

Wiring notes
  • 24 VDC control from onboard PSU
  • Contactor coils typically 24 VDC on smaller frames, 120 VAC on 50 hp+
  • RS-485 requires 120 Ω termination at each end
Known issues & field notes
  • ES3000 LCD backlight fades after ~7 years — replaceable as a module
  • PT100 harness clips at the airend loosen from vibration — a common intermittent shutdown source

Setup / service menu is protected by a 4-digit PIN, default 0000 on ES3000 and 2311 on ES4000 — change on commissioning.