CP Air Control / CP Touch

Chicago Pneumatic

AirCompDX - Field Reference for Air Compressor Techs

CP Air Control / CP Touch

Chicago Pneumatic industrial screws share a lot of DNA with Atlas Copco GA — sensor layouts and service kit categories are similar.

Manufacturer
Chicago Pneumatic
Display
CP Touch: 3.5"–5" color; CP Air Control: 4-line monochrome.
Years produced
CP Air Control ~2010 – 2019; CP Touch ~2019 – present.
Power supply
24 VDC control power.
Ambient range
0 – 46 °C.
Protection rating
IP54 front.
Relay outputs
Main / star / delta, blowdown, dryer, alarm.
Used on
  • CP QRS Series
  • CP CPVSd
  • CP CPB / CPC lines
On AirCompDX
Features
  • Multi-unit sequencing
  • Integrated dryer control on TS models
  • Event & trend logging
Interfaces
  • Ethernet Modbus TCP
  • USB service
  • Digital I/O
Sensor inputs
  • Airend discharge temp
  • Line pressure
  • Sump pressure
  • Separator ΔP
Common fault codes

Fault list is non-exhaustive and firmware-dependent. Always confirm against the controller’s on-screen help or OEM manual.

Wiring notes
  • 24 VDC control, similar architecture to Atlas Copco Elektronikon (shared parent)
Known issues & field notes
  • Some early CP Touch units ship with US-English only — Spanish/French pack via USB update
Manuals & literature
Chicago Pneumaticmanuals index

Parts & Services portal

Direct PDFs
  • Open
  • Open
Your manuals

Sign in to upload and pin your own PDF manuals to this controller.