BOGE focus control (1.0, original)
The original focus control shares sensor part numbers with focus control 2.0 but the CPU boards are NOT interchangeable. Upgrading a pre-2018 S-Series to 2.0 is a full panel swap, not a board swap.
Manufacturer
BOGE
Display
Monochrome graphic LCD with 6 membrane keys and LED status bar.
Years produced
~2008 – 2018. Superseded by focus control 2.0.
Power supply
24 VDC from onboard PSU (230 VAC primary on most EU packages).
Ambient range
0 – 46 °C.
Protection rating
IP54 front / IP20 rear.
Relay outputs
Main / star / delta contactors, blowdown solenoid, dryer enable, common alarm, remote-run.
Replaces
TOP control 2
Replaced by
focus control 2.0
Used on
- BOGE S-Series (pre-2018)
- BOGE C-Series screws
- BOGE SD/SF packages
Features
- Load/unload with adjustable minimum run and standstill timers
- Base-load changeover for up to 4 compressors without a master
- Hour and calendar service timers with 3 independent kits
- Weekly timer / remote start-stop
Interfaces
- RS-485 Modbus RTU
- Volt-free alarm & run contacts
- Optional Profibus card
Sensor inputs
- Airend discharge temp (PT1000)
- Sump pressure
- Line/network pressure
- Separator ΔP (option)
- Motor PTC
Fault code lookup
First checks
- Coolant level & cooler cleanliness
- Thermostatic valve stuck open
- PT1000 resistance ≈1385 Ω at 100 °C
First checks
- PTC continuity (cold ≈ 100–250 Ω)
- Motor cooling airflow
- Check for over-frequency starts/hour
First checks
- Verify all 3 phases at disconnect
- Swap two incoming legs
- Test phase-monitor relay
First checks
- Reset OL; compare draw to nameplate FLA
- Check voltage balance <2 %
- Look for airend drag
First checks
- Unload setpoint & deadband
- Inlet valve fails to close
- Pressure transducer drift — compare to gauge
First checks
- Shield grounded at one end only
- Check 4–20 mA loop at the terminal
- Substitute known-good sensor
First checks
- Release E-stop and reset
- Check remote loop jumper if unused
First checks
- Perform the specific kit
- Reset only the timer you completed
Fault list is non-exhaustive and firmware-dependent. Always confirm against the controller’s on-screen help or OEM manual.
Sensor pin resistance & signal values
Pin-level resistance and signal values for the sensor types this controller uses. Works offline. De-energise the panel and lift one lead before ohming any element.
Wiring notes
- 24 VDC control supply — a shared 24 V bus with the dryer is a common source of nuisance resets
- Blowdown solenoid needs a suppression diode across the coil to protect the output transistor
- RS-485 base-load link uses shielded twisted pair with 120 Ω terminators at each physical end
Known issues & field notes
- LCD contrast fades and pixel rows drop after ~8–10 years of hot-room service — display is a separate service part from the CPU
- Backup coin cell drains during long shutdowns; clock and hour meter reset on power-up
- Membrane keypad flexes at the 'Enter' key — hairline crack lets oil mist in
Two levels: operator (setpoints) and service. BOGE dealers set these at commissioning; there is no published universal code — if the service level is locked, BOGE service must reset it.