2/2-way solenoid opened for a set duration at a set interval to dump condensate from the receiver, dryer or separator.
Also called: timer drain · solenoid drain valve · EDV
De-energised state: NC
Normally closed — fails closed on power loss, so condensate backs up rather than blowing air.
How it works
A repeat-cycle timer energises a normally-closed 2/2 solenoid. Open time and interval are adjustable. Simple and cheap, but it dumps compressed air with the water — the reason zero-loss drains exist.
Coil resistance (typical, cold DC)
| Coil voltage | Resistance | Hold | Inrush |
|---|---|---|---|
| 24 VDC | 28 – 60 Ω | 9 – 20 W | — |
| 24 VAC | 8 – 25 Ω | 10 – 17 VA | 30 – 45 VA |
| 110–120 VAC | 180 – 600 Ω | 10 – 17 VA | 30 – 45 VA |
| 200–240 VAC | 700 – 2,400 Ω | 10 – 17 VA | 30 – 45 VA |
| 380–480 VAC | 2,800 – 9,000 Ω | 10 – 17 VA | 30 – 45 VA |
Typical values for the stated wattage class. Always compare against the coil tag. Open circuit = burnt winding; near 0 Ω = shorted turns.
Specifications
- Typical timer range
- Interval 0.5 – 45 min, duration 0.5 – 10 s
- Port
- 1/4" – 1/2" NPT
- Orifice
- 2 – 5 mm; use a strainer upstream
Parts you can order
- $60 – $180Generic / OEMTimed electronic drain valve (timer + solenoid)1/2 in. NPT timer drain kit
- $180 – $380JORCLOCK'N LOAD timer drainLOCK'N LOAD
- $190 – $620Ingersoll Rand (OEM)Electronic condensate drain (EDV / ELS)Serial-specific (IR parts portal)
Field test procedure
- Ohm the coil against its tag voltage using the table above.
- Force a manual test cycle: no click and no discharge with correct voltage present = failed coil or seized armature.
- Discharges air but no water = the drain leg is plugged upstream, or the interval is far too short.
Symptoms & probable causes
- Continuous air blowDebris on the seat or a failed timer output stuck on.
- Water carryover downstreamDrain not opening, plugged strainer, or interval too long.