LF16 (LF16-1H, LF16-4H)

Higher-pressure Lefoo for two-stage and 175 psi machines

All pressure switches
Lefoo · LF16

LF16 (LF16-1H, LF16-4H)

The LF16 is the heavier build of the Lefoo family, used where cut-out lands at 145–175 psi on two-stage recips and small screws. Same footprint family as the LF10 but with a stiffer diaphragm and a higher burst rating.

Specifications

Action
Standard — contacts open on rising pressure
Adjustable range
80–175 psi typical; builds to about 200 psi
Differential
30–45 psi (fixed)
Factory settings
120/150 psi · 145/175 psi
Ports
1/4 in. NPT single port or four-port manifold
Unloader
Unloader version available; required on any recip without a separate unloader
Lever / disconnect
Auto/off lever on the L builds
Enclosure
NEMA 1
Temperature
-22 °F to 257 °F

Electrical

  • 16–20 A at 120 VAC, 10–12 A at 240 VAC depending on build
  • DPST snap action, normally closed
  • Check the label rating against motor FLA before fitting

Size against motor full-load amps with the motor amperage calculator, and check feeder sizing with the voltage drop calculator.

Adjustment

  1. Set cut-out on the range nut and verify on a calibrated gauge — factory settings drift in shipping.
  2. Do not force a 175 psi setting on an LF10 body; the diaphragm is not rated for it.
Before you open the cover

Kill power at the disconnect and lock out. Bleed the tank to 0 psi. Never set cut-out above the tank data-plate MAWP. Verify your numbers first in the cut-in / cut-out calculator.

Best fit

  • Two-stage 175 psi shop compressors
  • Replacing an obsolete high-pressure OEM switch

Watch out

  • Fitting a 175 psi switch to a tank rated 150 psi is an ASME violation — check the tank plate, not the pump.
  • The safety valve must still be rated at or below the tank pressure after any setpoint change.

Cross-references

  • Square D 9013FHG42J59 (150 psi builds)
  • Furnas 69JF high-pressure builds