836T pressure control

NEMA-rated industrial pressure switch for panel and header duty

All pressure switches
Allen-Bradley (Rockwell) · 836T

836T pressure control

The 836T is the North-American industrial pressure control: piston or diaphragm sensing, adjustable range and differential, and enclosure options through NEMA 4X. Used on plant headers, large recips and as a high-pressure safety trip.

Specifications

Action
Standard — contacts open on rising pressure
Adjustable range
Wide by build — vacuum to several hundred psi
Differential
Adjustable (adjustable)
Factory settings
Field set
Ports
1/4 in. NPT typical
Unloader
None
Lever / disconnect
None
Enclosure
NEMA 1, 4, 4X and 7/9 builds
Temperature
Model dependent

Electrical

  • SPDT or DPDT pilot-duty contacts
  • Rated in VA for control circuits, not horsepower
  • Gold-plated contact option for low-current PLC inputs

Size against motor full-load amps with the motor amperage calculator, and check feeder sizing with the voltage drop calculator.

Adjustment

  1. Range and differential screws are separate and interact slightly — set, test, re-verify.
  2. For a PLC input, specify the gold contact option; standard silver contacts foul at milliamp currents.
Before you open the cover

Kill power at the disconnect and lock out. Bleed the tank to 0 psi. Never set cut-out above the tank data-plate MAWP. Verify your numbers first in the cut-in / cut-out calculator.

Best fit

  • Panel-mounted control and safety trips
  • Wash-down and outdoor installs needing NEMA 4X

Watch out

  • Order the enclosure rating for the environment, not the cheapest body — water ingress is the top failure mode.
  • Verify the pressure element material against the media; air and water are not the same spec as oil.

Cross-references

  • Danfoss KP/RT
  • Square D 9012/9013 industrial builds

Manufacturer documents