Cooling fan thermostat switch

Generic / universal · Cooling & fan control

All components

Bimetal or capillary switch that starts the cooler fan above a set oil/air temperature on cycling-fan packages.

Also called: fan thermal switch · temperature switch

De-energised state: NO

Normally open, closes on rise (typical). Some machines use close-on-fall NC types for heat-recovery dampers — read the tag.

How it works

A snap-action thermal switch mounted on the airend discharge or cooler header closes its contact at the set temperature to start the fan motor contactor, and reopens on a fixed differential.

Specifications

Typical set point
Closes 180 – 200 °F, opens ~20 °F lower
Contact rating
Pilot duty, 10 A @ 240 VAC typical

Parts you can order

  • Generic industrial
    Cooling fan thermostat switch
    By set temperature and switch action
    $30 – $130
Open the full parts database →

Field test procedure

  1. Ohm across the switch cold: NO type reads OL. Heat the sensing element and it should snap to < 1 Ω.
  2. Compare switching temp against an IR reading at the sensing point.

Symptoms & probable causes

  • High temperature trip with a cool cooler
    Fan switch not closing or fan contactor coil open.
  • Fan runs constantly, oil never warms
    Switch welded closed.