Atlas Copco Troubleshooting

Rotary screws (GA, GX), oil-free (ZR, ZT), and centrifugals (ZH). Elektronikon controller is standard.

AirCompDX - Field Reference for Air Compressor Techs
All brands
Typical models
GA-15GA-30 VSD+GX-7ZT-55
Field notes
  • Roto-Xtend Duty fluid is the OEM oil — 8,000 hr life; mixing with generic PAO cuts life to 4,000 hr.
  • Elektronikon MK5/MK5 Touch fault codes should always be pulled first — separator ΔP is stored trended.
  • GA units: verify SBV (solenoid blow-down valve) function on any hot-restart complaint.
Symptom → cause → fix

Won't build pressure / builds slowly

Likely causes
  • Worn intake or discharge reed valves
  • Blown head gasket between HP and LP chambers
  • Air leak in tank check valve or unloader
  • Loose or damaged intake filter
Fixes
  • Pull the head and inspect reeds — replace if cracked, curled, or carboned
  • Replace head gasket; torque head bolts in a star pattern to spec
  • Soap-test the check valve and tank fittings; replace check valve if seeping
  • Reseat or replace intake filter

Won't start / motor hums

Likely causes
  • Failed start (or run) capacitor
  • Pressure switch stuck closed above cut-out
  • Unloader valve not bleeding head pressure at shutdown
  • Thermal overload tripped and not reset
Fixes
  • Discharge and test capacitors with a meter; replace to nameplate µF
  • Bleed tank to zero; verify switch cut-in resets contacts
  • Verify unloader releases on shutdown; clean or replace
  • Let motor cool 15–30 min; press reset; investigate root cause (voltage, airflow)

Trips breaker or blows fuse

Likely causes
  • Motor drawing above FLA (worn bearings, seized pump)
  • Wrong breaker size or shared circuit
  • Extension cord causing voltage drop and locked-rotor current
  • Short in motor winding or capacitor
Fixes
  • Clamp-meter the motor at startup and run; compare to nameplate FLA
  • Verify dedicated circuit and breaker sized per NEC 430
  • Remove extension cord; wire direct or size per voltage-drop calc
  • Megger the windings; replace shorted capacitor or motor

Overheats / thermal trips under load

Likely causes
  • Blocked cooling fins or fan shroud debris
  • Low or degraded oil
  • High ambient / poor ventilation
  • Extended duty cycle beyond design
Fixes
  • Blow out fins with air; clear shroud and belt guard
  • Drain and refill oil; inspect for varnish
  • Relocate or add ventilation; keep 3 ft clearance minimum
  • Add tank capacity or step up to a higher-duty unit

Oil in air / excessive oil carryover

Likely causes
  • Worn piston rings or cylinder bore
  • Crankcase overfilled
  • Wrong oil viscosity or foaming oil
Fixes
  • Compression check per cylinder; rering or replace pump if below spec
  • Drain to sight glass mid-mark
  • Refill with OEM-spec non-detergent compressor oil

Excessive moisture in tank or lines

Likely causes
  • Tank drained infrequently
  • No aftercooler or dryer downstream
  • High humidity + long run time
Fixes
  • Drain tank daily (or install an auto-drain)
  • Add a refrigerated or desiccant dryer sized for your SCFM
  • Add a water separator + coalescing filter at point of use

Tank leak or rust weeping

Likely causes
  • Rust-through at the bottom (drain not used)
  • Cracked weld at a foot or handle bracket
  • Fitting or pressure relief valve threads leaking
Fixes
  • Replace the tank — welding an ASME/UL tank is not code-compliant
  • Re-tape fittings with PTFE; replace PRV if seeping
  • Establish a daily drain routine on the replacement
Deeper walkthroughs

General guidance for trained technicians. Always defer to the OEM service manual for your specific Atlas Copco model — pressures, torque values, and part numbers vary by production year.