Sullair LS-Series (LS 10–25S)
40–250 hp direct-drive oil-flooded rotary screw platform. Runs Sullube polyglycol fluid on 8k-hour change intervals.
- Load/Unload
- Modulation
- Dual Control
- VSD
- Heavy manufacturing
- Aerospace
- Petrochemical
- Marine
Specs & intervals below are from publicly published OEM literature and long-standing field practice. Torque values, exact revision-dated part numbers, and safety-critical settings vary by serial number — always cross-check the unit’s OEM manual and nameplate before ordering parts or performing service.
- AWF (elevated ambient)
- 24KT (high-hour hospital / hot ambient)
Separator canister torque per OEM sheet; MPCV spring preload set at factory — do not modify.
Always verify torque values against the OEM service manual for the specific serial number.
| Category | Interval | Source |
|---|---|---|
| Air filter (heavy-duty radial) | 2,000 hr or ΔP | |
| Fluid filter (spin-on or cartridge) | 2,000 hr | |
| Separator element | 4,000 hr | |
| Sullube fluid | 8,000 hr | |
| MPCV rebuild kit | 8,000 hr | |
| Coupling insert | Inspect at each service | |
| Motor bearings | Per motor plate |
Consumable part numbers change by revision and region — pull the current number from the OEM portal.
OEM part numbers with commonly-cited aftermarket equivalents. Verify against the nameplate and OEM parts portal before ordering — dimensionally similar filters can still be wrong for the application.
- P181054— Donaldson
- PA2848— Baldwin
- SA 16006— Hifi
- P550779— Donaldson
- B7350— Baldwin
- LF3335— Fleetguard
- SO 6603— Hifi
- P522449— Donaldson
- OAS30001— Baldwin
- OS 5205— Hifi
- PG-8000-32— Summit
- Compro XL-S 32— Petro-Canada
- PG-8000-32— SummitUnverified
- Compro XL-S 32— Petro-CanadaUnverifiedVerify PAG compatibility.
PAG lubricant. NEVER mix with PAO, diester, or petroleum.
Need to look up a number across all models? Use the parts cross-reference search.
- Check fluid level in sight glass at running temp
- Listen for unusual noise / vibration
- Check discharge pressure & temperature vs baseline
- Verify condensate drain function
- Log package amps if metered
- Blow down receiver and drain traps
- Check for oil carryover at first drop leg
- Inspect for fluid or air leaks around airend and separator tank
- Verify safety valve is not weeping
- Change fluid filter
- Change air filter (or sooner per ΔP)
- Sample fluid for TAN / metals / water
- Clean cooler exterior with low-pressure air (never > 30 psi against fins)
- Change separator element
- Change fluid
- Inspect scavenge line & orifice for coking
- Check coupling / belt alignment & wear
- Torque electrical lugs to spec (typ. 45–75 in-lb #4–2/0 AWG)
- Rebuild inlet valve
- Rebuild minimum-pressure check valve
- Regrease or replace motor bearings per OEM interval
- Verify safety valve setpoint against gauge
- High sump temp — thermal valve or cooler
- Change separator alarm — do fluid+filter as full kit
- Cold-start separator ΔP false alarm — recheck after 30 min run
- MPCV stuck at unload — sump won't blow down
- Sullube absorbs water aggressively — check for water in fluid at each PM in humid plants
- Retrofitting from Sullube to PAO requires 3 flushes with new fluid
- Sullair Supervisor / WS Controller — Supervisor: 5.7" color TFT with membrane keys; WS Signal: 4-line 20-char monochrome LCD.
- Sullube 8k-hour fluid life
- Robust for heavy-duty industrial
- Wide dealer network in NA
- Long airend life
- Sullube must not be mixed with mineral or PAO
- Retrofitting to non-Sullube fluid requires airend flush procedure
LS-Series is Sullair's core industrial screw. Available in fixed-speed and VSD.