California Air Tools SMART series (20040SM / 20040SMAD / 20040DSMAD)

20040SM, 20040SMAD, 20040SPCAD, 20040DSMAD, 20040DSMADC

California Air Tools SMART series (20040SM / 20040SMAD / 20040DSMAD)

Twin-pump 4 hp oil-free package with an electronic SMART controller, hour tracking and (on AD models) an automatic tank drain, aimed at clean-air duty in occupied spaces.

Type
Oil-less reciprocating
Power
4.0 hp, 220 V 60 Hz single-phase
Flow
12.80 cfm @ 40 psi, 10.6 cfm @ 90 psi
Pressure
Up to 125 psi, 20-gallon steel tank
Cooling
air
Drive
direct
Lubrication
oil-less
Models
20040SM, 20040SMAD, 20040SPCAD, 20040DSMAD, 20040DSMADC
Sound level
~75 dB(A) open frame; lower in the soundproof-cabinet (SPC) versions.
Starter
220 V single-phase with the SMART control board driving the motor contactor.
Integrated dryer
Dry-air variants advertise an integrated 80–98 % air dryer.
Typical applications
  • Dental and medical office air
  • Cabinet and finish shops
  • Labs and clean-air work
  • Any occupied space that cannot take an industrial recip

Specs & intervals below are from publicly published OEM literature and long-standing field practice. Torque values, exact revision-dated part numbers, and safety-critical settings vary by serial number — always cross-check the unit’s OEM manual and nameplate before ordering parts or performing service.

Fluid
Spec: None — oil-free twin-pump design
Change interval: N/A (oil-free)
Wear parts
CategoryIntervalSource
Intake filter elements (one per pump head)200 hours or on restriction
Automatic drain valve (AD models)Test monthly; clean the strainer annually
Piston cup / cylinder kits~3,000 hours per pump
Check valvesInspect annually
Dryer desiccant / refrigerated module (D models)Per the dryer's own schedule

Consumable part numbers change by revision and region — pull the current number from the OEM portal.

Preventive maintenance
Daily
  • Confirm the automatic drain cycled
  • Check delivered pressure against the SMART display
  • Listen for a pump running noticeably louder than its twin
Monthly
  • Manually test the auto drain
  • Check the intake filters
  • Verify the safety relief valve
Annual / 200 hr
  • Replace intake filters
  • Clean the cabinet air path and cooling fans
  • Verify cut-in/cut-out and hour meter against the controller
  • Inspect the contactor contacts
Common faults & first checks
  • One pump not starting — contactor or motor winding on that head; capacity halves and run time doubles
  • Auto drain not discharging — plugged strainer or a failed drain solenoid
  • SMART display showing overtemperature — blocked cabinet airflow or a jammed cooling fan
  • Long recovery time — worn piston cups, filter restriction, or a leaking check valve
Controller(s)
Strengths
  • Real CFM (10.6 @ 90) with no oil
  • Programmable SMART controller with hour tracking and auto drain
  • Soundproof-cabinet and integrated-dryer options
  • Suits medical/dental clean-air rules
Weaknesses
  • 220 V single-phase only
  • Expensive versus an industrial oil-lubed recip of the same CFM
  • Oil-free pumps still wear; plan on rebuild kits
  • Parts are brand-specific
Field notes

Ratings taken from the published 20040SMAD owner's manual and product page. Model suffixes change the cabinet, dryer and drain — check the data plate before ordering parts.