Annual AC / heat pump tune-up

PM

All guides
PM· Easy 60–90 min

Standard spring PM for a residential split system.

Tools
Coil cleaner · Fin comb · Manometer · Capacitance meter · Clamp meter
1

Kill power

Pull disconnect at outdoor unit and switch off the air handler breaker.

SafetyVerify absence of voltage before touching contactor.
2

Wash the condenser coil

Rinse from inside out with garden hose. Straighten bent fins with a fin comb.

3

Check capacitor(s)

Discharge, then measure µF vs nameplate. Replace if outside ±6%.

4

Tighten electrical

Torque contactor and disconnect lugs. Inspect wire for melt/pitting.

5

Change filter, clean blower

MERV 8–11. Inspect and brush blower wheel if dusty.

6

Verify charge

Superheat on fixed-orifice or subcool on TXV. Correct at 95°F outdoor / 80°F return.

7

Clear condensate

Vacuum outside termination; flush with vinegar solution.

8

Cycle and log

Record supply/return delta-T (18–22°F typical), amps, saturation temps.

Reference PDFs

in-app preview · thumbnails · search
Open
ENERGY STAR / EPA
Open
ENERGY STAR / EPA
Open
ENERGY STAR / EPA
Open
ENERGY STAR / EPA
Open
US Dept. of Energy
Open
US EPA