Compressor will not unload / stay unloaded

Won't run

All symptoms

Machine keeps running loaded past cut-out, or won't go to standby.

1

Unloader/inlet valve stuck open

Rotary screw
CheckWatch inlet valve butterfly at commanded unload — should close fully.
FixClean or rebuild inlet valve; check pilot solenoid and control air supply.
Sign in to rate whether this fix helped.
2

Pressure transducer reading low

Rotary screw
CheckCompare controller reading to a calibrated gauge at the same point.
FixReplace transducer; verify wiring and shield grounding.
ToolsCalibrated test gauge
Sign in to rate whether this fix helped.
3

Blowdown/vent solenoid failed

Rotary screw
CheckListen/feel for sump venting on unload command.
FixReplace solenoid coil or valve body.
Sign in to rate whether this fix helped.
4

Pressure switch contacts welded (recip)

Reciprocating
CheckWith power off (LOTO), inspect switch contacts for pitting/welding.
FixReplace pressure switch.
SafetyLOTO and verify zero energy before opening pressure switch enclosure.
Sign in to rate whether this fix helped.
5

Controller setpoint misconfigured

Rotary screw
CheckVerify unload/stop setpoint in HMI vs OEM defaults.
FixReprogram to correct value.
Sign in to rate whether this fix helped.

Did we solve your issue?

Sign in to share what resolved it and help others.

Field notes & discussion (0)

Share what actually fixed it. Comments are reviewed by a moderator before they go public.

Sign in to join the discussion.
Safety

Lockout/tagout before opening enclosures. Verify zero energy. Bleed system pressure before opening any pneumatic connection.