Standing water accumulating in receiver tank

Drain / condensate

All symptoms

Water is found inside the receiver during inspection or drain-down, risking internal corrosion.

1

Automatic drain not functioning

CheckManually actuate drain valve and observe discharge.
FixService or replace drain (see condensate-solenoid-failure and drain-stuck flows).
Sign in to rate whether this fix helped.
2

No aftercooler or undersized aftercooler upstream of tank

CheckMeasure air temperature entering the tank; compare to ambient.
FixAdd or upsize aftercooler so most moisture condenses upstream where it can be drained, not in the tank/piping.
Sign in to rate whether this fix helped.
3

Tank drain manual valve left closed after service

CheckVerify valve position; check maintenance log.
FixOpen/verify auto-drain path; establish a manual daily-drain checklist as backup.
Sign in to rate whether this fix helped.
4

Internal corrosion/pitting from prolonged water contact

critical
CheckHave the tank internally inspected per local pressure-vessel inspection requirements before returning to service.
FixRepair per code or replace the tank if corrosion compromises integrity — do not simply keep draining a corroding vessel.
SafetyA pressure vessel with significant internal corrosion is a rupture hazard; have it inspected by a qualified inspector.
Sign in to rate whether this fix helped.

Did we solve your issue?

Sign in to share what resolved it and help others.

Field notes & discussion (0)

Share what actually fixed it. Comments are reviewed by a moderator before they go public.

Sign in to join the discussion.
Safety

Lockout/tagout before opening enclosures. Verify zero energy. Bleed system pressure before opening any pneumatic connection.