CompDX

Trips breaker or overload

Electrical

All symptoms
1

Locked rotor / seized airend

CheckBar over by hand (lockout/tagout first). Should rotate freely.
FixIf seized, airend rebuild required.
2

Single-phasing (3Φ)

CheckMeasure all three legs at motor; check phase loss relay.
FixRestore lost phase; check fuses, contactor tips, terminations.
3

Low supply voltage

CheckVoltage at motor terminals under load — must be within ±10% nameplate.
FixCorrect supply; check wire size and length (voltage drop).
4

Wrong overload setting

CheckOL set to 115–125% of motor FLA on nameplate.
FixReset dial / select correct heater.
5

Discharge pressure above setpoint

CheckVerify pressure switch / load setpoint; verify unloader function.
FixAdjust setpoint; repair unloader.
6

Motor winding short / ground fault

CheckMegger windings to ground (>1 MΩ minimum).
FixRewind or replace motor.
Safety

Lockout/tagout before opening enclosures. Verify zero energy. Bleed system pressure before opening any pneumatic connection.