Short cycling (loads/unloads rapidly)

Pressure

All symptoms
1

Receiver too small for demand

CheckCalc: 1 gal per CFM minimum; 4 gal/CFM for variable loads.
FixAdd storage / dry receiver.
2

Cut-in/cut-out band too narrow

CheckTypical band 10–20 PSI.
FixWiden differential on pressure switch.
3

Leak in control air line

CheckSoap test pilot lines.
FixRepair.
4

Demand exceeds capacity

CheckLog run/unload times.
FixAdd compressor / fix leaks / reduce demand.
Safety

Lockout/tagout before opening enclosures. Verify zero energy. Bleed system pressure before opening any pneumatic connection.