Air leaking from pressure switch unloader while running (or never bleeds)

Controls

All symptoms

The small unloader valve on the side of the pressure switch should be closed while the motor runs, open for a moment when it stops (to dump the discharge line so the motor can restart unloaded), then close. Leaking while running wastes air; never bleeding causes hard starts and tripped breakers.

1

Unloader valve O-ring/pin worn — leaks while running

low
Reciprocating
CheckWith the pump running, soap-test the unloader. Bubbles = leak. Tank fills slower than normal.
FixReplace the unloader valve (often sold separately) or the whole pressure switch if integral.
Sign in to rate whether this fix helped.
2

Unloader lever bent or out of adjustment — never opens

med
Reciprocating
CheckStop the motor at cut-out: you hear no bleed puff. Then attempt restart with tank full: motor hums, struggles, or trips breaker.
FixAdjust or replace the unloader actuator; replace switch if the lever is part of the switch.
Sign in to rate whether this fix helped.
3

Bleeds constantly after stop — check valve leaking back

med
Reciprocating
CheckIf the bleed never stops after shutdown, the tank is emptying back through the line. See 'Tank check valve leaking back'.
FixClean/replace the tank check valve.
Sign in to rate whether this fix helped.

Did we solve your issue?

Sign in to share what resolved it and help others.

Field notes & discussion (0)

Share what actually fixed it. Comments are reviewed by a moderator before they go public.

Sign in to join the discussion.
Safety

Lockout/tagout before opening enclosures. Verify zero energy. Bleed system pressure before opening any pneumatic connection.