Gauge hunts up and down instead of holding a steady band.
1
Pressure transducer drifting or failing
medCheckCompare the controller reading with a calibrated test gauge at the same tap through a full cycle.
FixRecalibrate or replace the transducer; check for a blocked sense line.
ToolsCalibrated test gauge
Sign in to rate whether this fix helped.
2
Undersized receiver for a spiky demand
medCheckLog demand events; compare receiver volume against ≥1 gal per CFM (4 gal/CFM for variable load).
FixAdd receiver capacity, ideally near the large intermittent user.
Sign in to rate whether this fix helped.
3
Modulation / capacity control set too narrow
lowCheckReview the load/unload band — screws normally use 8–10 PSI, recips 10–20 PSI.
FixWiden the band to OEM values.
Sign in to rate whether this fix helped.
4
Faulty downstream regulator hunting
lowCheckIsolate the branch regulator and watch header pressure stabilise.
FixRebuild or replace the regulator; fit one sized for the actual flow.
Sign in to rate whether this fix helped.