1
Element fitted in the wrong housing or the wrong grade
medCheckCompare element part number and grade with the housing and the required air quality class.
FixFit the correct grade; particulate before coalescing, coalescing before carbon.
Sign in to rate whether this fix helped.
2
Filters installed in the wrong order
medCheckTrace the flow direction arrows from the header to the equipment.
FixRe-pipe in the correct sequence; a carbon tower ahead of a coalescer will be destroyed.
Sign in to rate whether this fix helped.
3
Bypass valve left open
highCheckCheck the bypass handle position and whether flow is actually passing through the treatment train.
FixClose and lock the bypass; tag it so it is only opened for element changes.
Sign in to rate whether this fix helped.
4
Unit undersized for the flow
medCheckCompare actual SCFM at that drop with the housing rating; check the ΔP at full flow.
FixUpsize the housing or add a parallel unit.
Sign in to rate whether this fix helped.