Refrigerated dryer dewpoint too high

Air treatment

AirCompDX - Field Reference for Air Compressor Techs
All symptoms
1

Inlet temperature too high

CheckInlet should be < 100°F (38°C); each 18°F rise doubles moisture load.
FixAdd aftercooler upstream; reduce ambient temp.
Sign in to rate whether this fix helped.
2

Condenser dirty (air-cooled)

CheckVisual; head pressure high.
FixBrush/blow out condenser fins.
Sign in to rate whether this fix helped.
3

Refrigerant low

high
CheckSuction/head pressures vs spec; sight glass for bubbles.
FixFind leak first; recharge with correct refrigerant.
Sign in to rate whether this fix helped.
4

Hot gas bypass valve out of adjustment

CheckEvaporator outlet temp swinging.
FixAdjust HGBV per manual.
Sign in to rate whether this fix helped.
5

Heat exchanger fouled internally

CheckΔP high; performance drops despite refrigerant ok.
FixChemical clean or replace exchanger.
Sign in to rate whether this fix helped.

Did we solve your issue?

Sign in to share what resolved it and help others.

Safety

Lockout/tagout before opening enclosures. Verify zero energy. Bleed system pressure before opening any pneumatic connection.