CompDX

Contactor chattering or burning

Electrical

All symptoms
1

Low control voltage

CheckMeasure coil voltage while attempting pull-in. Must be ≥85% of rated.
FixCheck transformer, control wiring length, dropping resistors.
2

Pitted / welded tips

CheckVisual; measure mV drop across closed tips.
FixReplace tips or contactor.
3

Undersized contactor for FLA

CheckVerify NEMA/IEC rating ≥ motor FLA.
FixUpsize.
4

Loose terminations causing arcing

CheckIR camera; torque check.
FixRe-torque to spec.
Safety

Lockout/tagout before opening enclosures. Verify zero energy. Bleed system pressure before opening any pneumatic connection.